Covered Line ÌÇÐÄVlog´«Ã½ ACSR Aluminum Conductor
Covered AL Line ÌÇÐÄVlog´«Ã½ Weatherproof
Applications
Covered Line ÌÇÐÄVlog´«Ã½ is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
Construction
Aluminum alloy 1350-H19 wires concentrically stranded over a steel wire core. The steel wire core is Class A Zinc coated (Code GA2). The conductor is covered with linear-low density polyethylene (LLDPE).
Standards
Covered Line ÌÇÐÄVlog´«Ã½ is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
Construction
Aluminum alloy 1350-H19 wires concentrically stranded over a steel wire core. The steel wire core is Class A Zinc coated (Code GA2). The conductor is covered with linear-low density polyethylene (LLDPE).
Standards
-
ASTM B230 – Aluminum 1350–H19 ÌÇÐÄVlog´«Ã½ for Electrical Purposes
-
ASTM B231 – Concentric-Lay-Stranded Aluminum 1350 Conductors
-
ASTM B232 – Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)
- ASTM B498 – Zinc-Coated (Galvanized) Steel Core ÌÇÐÄVlog´«Ã½ for Use in Overhead Electrical Conductors
- CSA C60888 – Zinc-coated steel wires for stranded conductors
- CSA C60889 – Hard-drawn aluminum wire for overhead line conductors
- CSA C61089 – Round wire concentric lay overhead electrical stranded conductors
- ASTM D1248 – Polyethylene Plastics Extrusion Materials for ÌÇÐÄVlog´«Ã½ and Cable
1) Dimensions and weights are subject to standard manufacturing tolerances and are subject to change without notice.
2) Resistance is calculated using metal conductivity of 61.2% IACS for EC (1350) at 20ºC and 8% IACS for steel at 20ºC.
3) Ampacities are based on 75ºC conductor temperature, 25ºC ambient, 2 ft/s wind, full sun, an emissivity of 0.91 and a coefficient of solar absorption of 0.91, at sea level. Thermal resistivity of covering is 375ºC-cm/Watt.
UPDATED 06/12/2023
Unit of Measure
| Items |
/Asset/AL-Weatherproof-Line-ÌÇÐÄVlog´«Ã½.png Walnut Covered Line ÌÇÐÄVlog´«Ã½ ACSR Aluminum Conductor |
/Asset/AL-Weatherproof-Line-ÌÇÐÄVlog´«Ã½.png Butternut Covered Line ÌÇÐÄVlog´«Ã½ ACSR Aluminum Conductor |
/Asset/AL-Weatherproof-Line-ÌÇÐÄVlog´«Ã½.png Hickory Covered Line ÌÇÐÄVlog´«Ã½ ACSR Aluminum Conductor |
/Asset/AL-Weatherproof-Line-ÌÇÐÄVlog´«Ã½.png Pignut Covered Line ÌÇÐÄVlog´«Ã½ ACSR Aluminum Conductor |
/Asset/AL-Weatherproof-Line-ÌÇÐÄVlog´«Ã½.png Beech Covered Line ÌÇÐÄVlog´«Ã½ ACSR Aluminum Conductor |
|||||
|
Size AWG /KCMIL |
N/A 6 | N/A 4 | N/A 4 | N/A 2 | N/A 2 | |||||
| Stranding | N/A 6/1 | |||||||||
|
Conductor Diameter (in) |
N/A 0.198 | N/A 0.250 | N/A 0.257 | N/A 0.316 | N/A 0.325 | |||||
|
Covering Thickness (in) |
N/A 0.030 | N/A 0.030 | N/A 0.030 | N/A 0.045 | N/A 0.045 | |||||
|
Overall Diameter (in) |
N/A 0.258 | N/A 0.310 | N/A 0.317 | N/A 0.406 | N/A 0.415 | |||||
|
AL Weight (lb/1000 ft) |
N/A 24.5 | N/A 38.9 | N/A 38.9 | N/A 61.9 | N/A 61.9 | |||||
|
STEEL Weight (lb/1000 ft) |
N/A 11.6 | N/A 18.4 | N/A 28.0 | N/A 29.3 | N/A 44.7 | |||||
|
NET Weight (lb/1000 ft) |
N/A 45.5 | N/A 68.8 | N/A 78.7 | N/A 113.5 | N/A 129.5 | |||||
|
Rated Strength |
N/A 1190 | N/A 1860 | N/A 2360 | N/A 2850 | N/A 3640 | |||||
|
DC Resistance @ 20 deg C (ohm/1000 ft) |
N/A 0.6410 | N/A 0.4030 | N/A 0.3990 | N/A 0.2540 | N/A 0.2510 | |||||
|
Ampacity (A) |
N/A 105 | N/A 140 | N/A 140 | N/A 185 | N/A 180 | |||||
|
|
||||||||||