Applications
Covered Line ÌÇÐÄVlog´«Ã½ is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.

Construction
Conductors are aluminum alloy 1350-H19, 6201-181, or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HD) or crosslinked polyethylene (XLP).

Standards
  • ASTM B-230 - Aluminum 1350-H19 ÌÇÐÄVlog´«Ã½ for Electrical Purposes.
  • ASTM B-231 - Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
  • ASTM B-1248 - Polyethylene Plastics Molding and Extrusion Materials.
  • ASTM C-8.35 - Specifications for Weather-Resistant Polyethylene-Covered ÌÇÐÄVlog´«Ã½ and Cable.
  • ICEAS-61-402
  • NEMA PUB NO. WC 5-1973 - Standards Publication Thermoplastic insulated ÌÇÐÄVlog´«Ã½ and Cable for the Transmission and Distribution of Electrical Energy.
Notes
  • The code words as given apply to conventional polyethylene line wire.
  • For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum equivalent.
  • Ampacity ratings based on 75 ºC conductor temperature, 25 ºC ambient temperature elevation - sea level. Emissivity 0.91 coefficient of absorption 0.95. Thermal resistivity of covering -3ºC-Cm2/Watt-CM. Wind speed 2ft/sec in sun.
  • To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Unit of Measure

Specifications

Code Name

N/A Planetree

Size
(AWG or kcmil)

N/A 4/0

Strand

N/A 7/w

Insulation
Thickness
(mils)

N/A 60 mls

Outside
Diameter

N/A .683 Inches

Rated
Breaking
Strength

N/A 7700 Lbs

Weight
Per
(lb/1000 ft)
XLP

N/A 307.3 Lbs

Weight
(lb/1000 ft)
Poly

N/A 298.1 Lbs

Ampacity
XLP

N/A 385 Amps