Copper Duplex Service Drop Cable
Duplex Service Drop Cable
Copper Conductor
Copper Conductor
Application
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 潞C for polyethylene insulated conductors and 90 潞C for cross-linked polyethylene (XLP) insulated conductors.
Specifications
Meets or exceeds the following ASTM specifications:
Construction
Conductors are concentrically stranded compressed soft copper insulated with either cross-linked polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.
Notes:
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 潞C for polyethylene insulated conductors and 90 潞C for cross-linked polyethylene (XLP) insulated conductors.
Specifications
Meets or exceeds the following ASTM specifications:
- B-1 Hard-Drawn Copper 糖心Vlog传媒.
- B-3 Soft or Annealed Copper 糖心Vlog传媒.
- B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft.
Construction
Conductors are concentrically stranded compressed soft copper insulated with either cross-linked polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.
Notes:
- Code words for XLP insulated products are formed by adding ""XLP"" to the conventional polyethylene code words above (e.g.-Theta/XLP).
- Ampacity figures for black insulation only. Based on conductor temperature of 75 潞C for polyethylene insulated conductors, 90 潞C for XLP insulated conductors, ambient temperature of 40 潞C 2 ft./sec. wind in sun.
Item # |
Phase
|
Phase
|
Phase
|
Neutral
|
Neutral
|
Neutral
|
Nominal
|
Weight
|
Weight
|
Allowable
|
Allowable
|
|---|---|---|---|---|---|---|---|---|---|---|---|
| Theta Theta/Asset/CU-DUPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 8 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 10 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 529 |
Nominal Lay Length (inches) N/A 10.36 |
Weight (lb/1000 ft) XLP N/A 96 |
Weight (lb/1000 ft) Poly N/A 97 |
Allowable Ampacities XLP N/A 85 |
Allowable Ampacities Poly N/A 70 |
| Omega Omega/Asset/CU-DUPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 8 |
Phase Conductor Stranding N/A 1 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 8 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 826 |
Nominal Lay Length (inches) N/A 10.36 |
Weight (lb/1000 ft) XLP N/A 112 |
Weight (lb/1000 ft) Poly N/A 113 |
Allowable Ampacities XLP N/A 85 |
Allowable Ampacities Poly N/A 70 |
| Iota Iota/Asset/CU-DUPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 8 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 8 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 826 |
Nominal Lay Length (inches) N/A 10.36 |
Weight (lb/1000 ft) XLP N/A 115 |
Weight (lb/1000 ft) Poly N/A 116 |
Allowable Ampacities XLP N/A 85 |
Allowable Ampacities Poly N/A 70 |
| Kappa Kappa/Asset/CU-DUPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 8 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 8 |
Neutral Messenger Stranding N/A 7 |
Neutral Messenger Rated Strength (lbs.) N/A 777 |
Nominal Lay Length (inches) N/A 10.36 |
Weight (lb/1000 ft) XLP N/A 116 |
Weight (lb/1000 ft) Poly N/A 117 |
Allowable Ampacities XLP N/A 85 |
Allowable Ampacities Poly N/A 70 |
| Lambda Lambda/Asset/CU-DUPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 6 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 8 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 826 |
Nominal Lay Length (inches) N/A 10.36 |
Weight (lb/1000 ft) XLP N/A 149 |
Weight (lb/1000 ft) Poly N/A 149 |
Allowable Ampacities XLP N/A 110 |
Allowable Ampacities Poly N/A 90 |
| Omicron Omicron/Asset/CU-DUPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 6 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 6 |
Neutral Messenger Stranding N/A 1 |
Neutral Messenger Rated Strength (lbs.) N/A 1280 |
Nominal Lay Length (inches) N/A 10.36 |
Weight (lb/1000 ft) XLP N/A 179 |
Weight (lb/1000 ft) Poly N/A 179 |
Allowable Ampacities XLP N/A 110 |
Allowable Ampacities Poly N/A 90 |
| Sigma Sigma/Asset/CU-DUPLEX-SERVICE-DROP.jpg |
Phase Conductor Size AWG N/A 6 |
Phase Conductor Stranding N/A 7 |
Phase Conductor Cover Thickness (mils) N/A 45 |
Neutral Messenger Size AWG N/A 6 |
Neutral Messenger Stranding N/A 7 |
Neutral Messenger Rated Strength (lbs.) N/A 1228 |
Nominal Lay Length (inches) N/A 10.36 |
Weight (lb/1000 ft) XLP N/A 180 |
Weight (lb/1000 ft) Poly N/A 181 |
Allowable Ampacities XLP N/A 110 |
Allowable Ampacities Poly N/A 90 |