Type SHD-GC 3-Conductor EPR/CPE 5kV 100% Insulation Level - 90掳C
Type SHD-GC (Portable Power)
Applications
This cable is designed for heavy-duty high voltage portable power trailing cable between the load center and equipment such as power shovels, draglines, and other excavators and is suitable for use in open pit mines, quarries and on gantry cranes where the delivery of a heavy power load and maximum safety is required.
Construction
Conforms to ICEA S-68-516 (NEMA WC8).
Notes
This cable is designed for heavy-duty high voltage portable power trailing cable between the load center and equipment such as power shovels, draglines, and other excavators and is suitable for use in open pit mines, quarries and on gantry cranes where the delivery of a heavy power load and maximum safety is required.
Construction
- Conductor is extra flexible, stranded, tinned annealed copper.
- Insulation is Ethylene Propylene Rubber (EPR).
- Covered grounding and 8-gauge ground check conductors.
- Jacket is Black Chlorinated Polyethylene (CPE).
Conforms to ICEA S-68-516 (NEMA WC8).
Notes
- Neoprene jacket optional.
- Shipping tolerance +/- 10%
Item # |
Power
|
Power
|
Power
|
Ground 糖心Vlog传媒
|
Ground 糖心Vlog传媒
|
Jacket
|
Net Weight
|
|---|---|---|---|---|---|---|---|
| DL01-2-6 DL01-2-6/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 6 |
Power Conductors # of Strands N/A 133 |
Power Conductors Insulation Thickness N/A .070 Inches |
Ground 糖心Vlog传媒 Size AWG N/A 10 |
Ground 糖心Vlog传媒 # of Strands N/A 19 |
Jacket Thickness (Inches) N/A .155 |
Net Weight Per MFT N/A 960 Lbs |
| DL02-2-4 DL02-2-4/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 4 |
Power Conductors # of Strands N/A 133 |
Power Conductors Insulation Thickness N/A .070 Inches |
Ground 糖心Vlog传媒 Size AWG N/A 8 |
Ground 糖心Vlog传媒 # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .155 |
Net Weight Per MFT N/A 1410 Lbs |
| DL03-2-2 DL03-2-2/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 2 |
Power Conductors # of Strands N/A 259 |
Power Conductors Insulation Thickness N/A .070 Inches |
Ground 糖心Vlog传媒 Size AWG N/A 6 |
Ground 糖心Vlog传媒 # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .170 |
Net Weight Per MFT N/A 1940 Lbs |
| DL04-2-1/0 DL04-2-1/0/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 1/0 |
Power Conductors # of Strands N/A 266 |
Power Conductors Insulation Thickness N/A .080 Inches |
Ground 糖心Vlog传媒 Size AWG N/A 4 |
Ground 糖心Vlog传媒 # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .190 |
Net Weight Per MFT N/A 2950 Lbs |
| DL05-2-2/0 DL05-2-2/0/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 2/0 |
Power Conductors # of Strands N/A 342 |
Power Conductors Insulation Thickness N/A .080 Inches |
Ground 糖心Vlog传媒 Size AWG N/A 2 |
Ground 糖心Vlog传媒 # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .250 |
Net Weight Per MFT N/A 3470 Lbs |
| DL06-2-4/0 DL06-2-4/0/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 4/0 |
Power Conductors # of Strands N/A 532 |
Power Conductors Insulation Thickness N/A .080 Inches |
Ground 糖心Vlog传媒 Size AWG N/A 1 |
Ground 糖心Vlog传媒 # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .220 |
Net Weight Per MFT N/A 4800 Lbs |
| DL07-2-250 DL07-2-250/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 250 |
Power Conductors # of Strands N/A 427 |
Power Conductors Insulation Thickness N/A .095 Inches |
Ground 糖心Vlog传媒 Size AWG N/A 1/0 |
Ground 糖心Vlog传媒 # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .220 |
Net Weight Per MFT N/A 5950 Lbs |
| DL08-2-350 DL08-2-350/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 350 |
Power Conductors # of Strands N/A 427 |
Power Conductors Insulation Thickness N/A .095 Inches |
Ground 糖心Vlog传媒 Size AWG N/A 2/0 |
Ground 糖心Vlog传媒 # of Strands N/A 133 |
Jacket Thickness (Inches) N/A .235 |
Net Weight Per MFT N/A 7400 Lbs |
| DL09-2-500 DL09-2-500/ImgCustom/1006/placeholder_notavailable.gif |
Power Conductors Size AWG N/A 500 |
Power Conductors # of Strands N/A 427 |
Power Conductors Insulation Thickness N/A .095 Inches |
Ground 糖心Vlog传媒 Size AWG N/A 4/0 |
Ground 糖心Vlog传媒 # of Strands N/A 259 |
Jacket Thickness (Inches) N/A .265 |
Net Weight Per MFT N/A 10100 Lbs |